What Is SEER2? Efficiency Rating on an HVAC Permit

The efficiency number on an AC or heat pump nameplate that permit offices and inspectors check.

Updated November 2026 Glossary Term

SEER2: A federal efficiency rating for central air conditioners and heat pumps that measures cooling output over a season relative to electricity used, measured under a newer test than the older SEER rating.

What SEER2 Measures

SEER2 stands for Seasonal Energy Efficiency Ratio 2. It describes how much cooling a central air conditioner or heat pump delivers for each unit of electricity over a season. A higher number means a more efficient unit. Federal testing procedures changed in 2023, and SEER2 is the rating that follows the newer procedure, which reflects the airflow resistance found in real duct systems.

You will see it on the equipment label, the manufacturer's data sheet and the contractor's quote.

Heat pumps also carry a heating efficiency rating, HSPF2, which appears alongside SEER2 on the same label.

Why It Shows Up on a Permit

HVAC permit applications often ask for the model number, the capacity and the efficiency rating. The reviewer or inspector uses them to confirm that the installed equipment meets the federal minimum and any local energy code requirement. A model number lets the office look up the rating, and a mismatch between the label and the application is a common reason for a correction.

See energy code and mechanical permit for the related rules.

The approval of the permit does not depend on a particular brand, only on the rating and the code.

Keep the equipment data sheet with your closeout papers; it is the document an inspector or later buyer will ask for if the rating is questioned.

Regional Minimums

Federal rules set minimum efficiency by region, with colder northern states and warmer southern states having different minimums for newly installed central air conditioners. A unit that may be installed in one region may not be allowed in another, which is a point contractors and inspectors check. Your contractor knows the minimum for your region, and the permit office can confirm what it enforces.

Some utilities and incentive programs use higher efficiency ratings than the legal minimum.

Changes in federal minimums over the years mean an older quote may list equipment that can no longer be installed new in your region.

Where SEER2 Comes Up on This Site

It is on HVAC permits and appears indirectly in our HVAC replacement rules research, which compares whether cities treat an AC swap as needing a permit. The HVAC permit guide lists the documents a typical application includes.

The cities' own pages say whether the efficiency sheet must be attached.

Equipment efficiency is typically the contractor's responsibility to document, so ask for the model number and rating sheet early. The city page for your location says what the office needs to see at application and at inspection.

Frequently Asked Questions

Both describe seasonal cooling efficiency, but SEER2 uses a newer federal test that better reflects real duct conditions, so the same unit rates a little lower under SEER2. Equipment labels now show SEER2. The numbers should not be compared directly across the two scales.
Your permit requires that the equipment meet the federal minimum for your region and any stricter local energy code. A higher rating than the minimum is usually your choice, though some incentive programs require it. The permit office or your contractor can confirm the minimum that applies.
On the yellow efficiency label, the nameplate on the outdoor unit and the manufacturer's data sheet. For permit applications, the contractor typically supplies the model number and the rating. If you only have the model number, the manufacturer's website or an AHRI directory can show the rating.