Tamper-Resistant Receptacle: What It Means

An outlet with internal shutters that keep children from pushing objects into the slots.

Updated November 2026 Glossary Term

Tamper-Resistant Receptacle: A wall outlet with spring-loaded internal shutters that open only when a plug pushes both prongs in at once. The National Electrical Code requires them in dwellings, and they are marked TR.

What Makes an Outlet Tamper-Resistant

Behind the face of a tamper-resistant receptacle sit two small shutters. A plug pushes both open together. A hairpin, key or screwdriver pushed into one slot meets a closed shutter and goes nowhere. The device is stamped TR on the face, costs only a little more than a standard outlet and installs exactly the same way, so nothing about the wiring changes.

The purpose is child safety. The shutters were added because small children were being hurt by pushing objects into outlets, and the rule now covers nearly every household outlet that is not out of reach.

Where the Code Requires Them

The National Electrical Code (NEC) has required tamper-resistant receptacles in new dwelling units since the 2008 edition, and later editions have extended the list to more locations such as guest rooms, child care spaces and more areas in and around the home. The International Residential Code (IRC) follows the NEC for electrical work in one- and two-family homes. Typical exceptions are outlets more than a certain height above the floor, outlets behind appliances and outlets that serve a dedicated appliance. Your state or city decides which edition applies, so local adoption varies.

When a Permit Brings It Up

A new outlet in a permitted project is expected to be tamper-resistant, and a permit inspector will often check the TR mark during the rough-in or final inspection. The rule also reaches replacements: under the NEC, when a receptacle is replaced in a location that requires tamper-resistant protection, the new one has to be TR as well. That means a homeowner swapping a worn outlet may be bound by the rule even without a permit, and a permitted remodel is checked against it.

If a bathroom or kitchen remodel includes new outlets, the plan reviewer expects TR devices together with GFCI protection. See GFCI for the shock-protection side of the same outlet.

Where It Comes Up on This Site

Outlets are part of every wiring scope this site covers. The panel and service work in the electrical panel permit guide and the room-level scope in the bathroom remodel research both end in an inspection where receptacle type is on the checklist. Which jobs need a permit at all varies by city, and the research pages compare those rules city by city. If you are only replacing a worn outlet, check whether your city lists a like-for-like swap as exempt before you decide whether to call for an inspection.

Frequently Asked Questions

Not literally everywhere. The NEC requires them in most 125-volt, 15- and 20-amp locations in dwelling units, with exceptions such as outlets placed high on a wall, behind appliances and some dedicated appliance outlets. Which NEC edition applies is a local decision, so the exact list depends on your city.
In many places a like-for-like outlet swap is exempt from a permit, but the replacement still has to meet the code, which means a TR receptacle where one is required. Some cities do require a permit for any electrical work, so check your building department before you start.
Look for the letters TR on the face of the receptacle, often near the ground hole or on the yoke. You can also see two shutters behind the slots with a flashlight. Older outlets lack the mark and are not required to be replaced unless you are changing them or doing permitted work.