What Is Stair Rise and Run on an Inspection?

The height and depth of each step, which inspectors check for size and consistency.

Updated November 2026 Glossary Term

Stair Rise and Run: The vertical height of each stair step, called the rise or riser, and the horizontal depth of each tread, called the run, set within code limits and kept uniform along the flight.

Rise and Run Defined

Every stair step has a vertical part and a horizontal part. The rise is the height from one tread to the next, and the run is the depth of the tread you step on. Together they set how steep the stair feels. Too much rise or too little run makes a steep stair that is hard to use and more likely to cause falls.

Stairs also have a headroom requirement above them and a minimum width.

Landings are required at the top and bottom of most stairs, and a door swinging over a stair needs its own landing.

Common Model Code Limits

Under the International Residential Code, a typical house stair has a maximum riser height and a minimum tread depth, with a limit on how much they may vary within one flight. The common figures are about 7 and three-quarter inches for the riser and 10 inches for the tread, with a small allowed variation. Spiral stairs and winders have their own rules.

These are model code figures, and local adoption varies, so follow your city's version of the stair rules.

Open risers, nosing and the shape of the tread edge are also regulated in many codes.

A common failure is a bottom or top step that differs from the rest because of a finish floor laid after the stair was framed.

Why Uniformity Matters

People walk stairs without looking, and rely on each step being the same. A step that is even slightly taller or shorter than the others is a common cause of falls. For that reason, inspectors measure the first and last riser and several in between, and the code limits the difference between the tallest and shortest.

Concrete or finished flooring added later can change a riser, which is why inspectors check before finish materials go on in some places.

Measure from the finished surfaces, since flooring thickness changes the actual riser.

Where Stair Geometry Comes Up on This Site

Stairs appear on deck permits, additions, basement and garage conversions and ADUs. Our deck permit guide, garage conversion guide and ADU permit guide cover those projects.

See handrail and guardrail for the related rails.

On a deck, a stair adds a landing and guard questions, and in a remodel a new stair affects the framing around it. Stair plans usually show the total rise, the number of steps and the tread depth so the reviewer can calculate each riser. Cities differ on the details, so use your city's page.

Frequently Asked Questions

The International Residential Code commonly caps it at about 7 and three-quarter inches for a house stair, with a minimum tread of about 10 inches. Local adoption varies, so check your city's version before cutting stringers or ordering a prefabricated stair.
Because inconsistent steps cause falls. Even a small difference in riser height between steps can catch a foot. The code limits how much risers and treads may vary within a flight, so inspectors measure several and compare the tallest to the shortest.
Special cases such as spiral stairs, alternating tread devices or ladders for lofts are treated differently, and where they are allowed depends on the code and the use. Do not assume a steeper stair passes; ask the permit office for the rule that applies.
Stay up to date
Get notified when we add new cities or update permit fees.